Bar Spacer 2dol
Description
Bar Spacer 2dol
The plastic bar spacer 2dol with standard size and the possibility of placing two reinforcement rebar has been designed and manufactured. To determine the correct distance for trusses and put them in metal molds, joists or fondoleh.

Applications:
- Determining the correct distance for the ready joist trusses
- For direct joist and only using truss and joist spacer in the empty space between waffle blocks
- Two lockers on both sides
- Ability to fit rebar from 6 to 14 mm in diameter
- Capable of bearing spot load up to 50 kg
packing :
| Name | Concrete Cover | Bar size | Packing (QTY) | WEIGHT (KG) |
| Bar space 2Dol | 15 | 6-16 | 500 | 6/8 |
Product Description – Double Reinforcement Beam Spacer
The efficiency of ready-made standard trusses for making beams has long been a matter of concern to respected contractors. These ready-made trusses are manufactured in the factory according to the desired details and transported to the project site or beam-making workshop. Basically, during the transportation of the trusses or their unloading and loading, the angle of the ready-made truss is likely to change or become complicated. For this reason, it is necessary to adjust this distance before using the trusses to make beams, which is a difficult and time-consuming task and usually does not yield the desired result. To solve this problem, the double-reinforced beam plastic spacer has been designed and produced with a standard size and the ability to accommodate two reinforcing bars. The double-reinforced beam plastic spacer is an efficient product for determining the appropriate distance for ready-made beam trusses and placing them inside the metal forms of the beam or foundation. In addition to having two locks on both sides, this product has two locking handles in the middle, which are specifically designed for placing reinforcing bars. Beam spacers can also be used in modern construction technologies, for example, in hollow slab roofs (waffle roofs) for direct beam placement using only trusses and beam spacers in the empty space between the waffle blocks. The double-reinforced beam spacer is capable of accommodating rebar from 6 to 14 mm in diameter within its holders and is capable of withstanding point loads of up to 50 kg.
In general, this piece of spacer can create a suitable distance between the steel rebar of the concrete. Also, the main purpose of the birth of the presented product is to provide easy and high quality in the connections of the rebar and in all types of beams.
Note: The plastic spacer of the double-beam reinforcement creates a 15 mm concrete cover on the rebar.
This Beam Spacer 2Dol product is a special spacer that is modeled for use in beams and is used to maintain the proper distance and position of two rows of rebar inside the beams. These types of parts play an important role in ensuring the quality and strength of concrete structures. This spacer is an efficient tool in the construction industry that can help improve the quality and durability of concrete structures by maintaining the correct distance and position of two rows of rebar. Using this plastic spacer protects the rebar from environmental factors and makes the structures more resistant.
How to use double-reinforced beam spacers
What is the method of using a double-reinforced beam spacer?
Making a beam:
At the required intervals, the joist or foundation is placed inside the metal formwork, then the joist truss is placed inside the locking lugs and the reinforcing bars are placed inside the locking lugs.
Transportation of ready-made trusses and beams:
When transporting the finished trusses from the factory to the project, they are installed on the main truss bars to prevent deformation, and then loaded onto the machine.
Waffle molds (hollow slab ceilings)
The plastic spacer of the double-reinforced beam is placed at regular intervals in the empty space between the blocks, and then the prepared truss of the beam is placed inside the brackets, and finally the reinforcing bars are placed.
Consumption of double-reinforced beam spacers
What is the size of the spacer bar for the double-reinforced beam?
Transportation of ready-made trusses and beams:
One spacer is required for every 2 meters of the length of the truss.
Making a beam:
For every meter of joist length, 1 joist spacer is required.
Use in waffle molds (hollow slab ceilings):
Place joist spacers at intervals of 75 centimeters from each other.
Important points about double-reinforced beam spacers
What are the necessary tips for using double-reinforced beams?
- Failure to utilize this product can cause harmful damage in terms of deformation of trusses and twisting of beams, resulting in structural weakness.
- Using a double-reinforced plastic beam spacer significantly reduces the cost of beam construction, transportation to the project, and implementation time in hollow-core slab projects.
- Using a double-reinforced beam spacer will produce quality beams, while adhering to relevant details in accordance with the standard.
Double-reinforced beam spacer packaging
| Product name | Concrete coating | Size | Quantity in package | Package weight |
| Name | Concrete Cover | Size | Packing (QTY) | WEIGHT (KG) |
| Double-reinforced beam spacer
Bar space 2Dol |
15 | 6 – 16 | 500 | 6/8 |






Reviews